Xgard Detectors for flammable, toxic and oxygen gases

General Details

The Xgard range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.

Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL, GOST-R and MED

Features

Low cost of ownership

  • Designed for easy installation and maintenance – keeps costs down
  • Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
  • Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum

Flexible installation options

  • Designed for either wall or ceiling mounting – no need for additional brackets
  • Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
  • High temperature models are available for hot environments (up to 150oc)
  • Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking

Wide range of sensors

  • Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
  • Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
  • Thermal conductivity sensors are available to monitor % volume concentrations of gases

Rugged and reliable

  • Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
  • Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)
Specification

Types 1,2 and 3. Jump to Types 4, 5 and 6.

Type 1 Type 2 Type 3
Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs)
Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel
Ingress protection IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type Electrochemical Catalytic bead
Operating temperature -40 to +50°C
(-40 to 122°F)
(sensor dependant)
 -20 to +50°C (-4 to 122°F) -40 to +80°C
(-40 to 176°F)
Humidity 10 to 95% RH non-condensing  0-99% RH non-condensing
Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
Response time T90  T90
Operating voltage 8-30V dc   2.0V dc +/- 0.1V (Typical)
Power requirements 24mA maximum 300mA (Typical)
Electrical output 2- wire 4-20mA (current sink)  3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4
Approvals ATEX: II 1 GExia IIC T4 Ga (Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECEx
GOST-R
ATEX: II 2 GDExia IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECEx
GOST-R
ATEX: II 2 GDExia IIC T4 Gb (Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
GOST-R
EMC compliance EN 50270FCC Part 15    ICES- 003

Types 4, 5 and 6

Type 4 Type 5 Type 6
Size 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight 1.5 kg (3.3lbs)  Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs)
Enclosure material Aluminium  Aluminium or 316 Stainless Steel
Ingress protection IP54  IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity
Operating temperature  -20 to +150°C (-4 to 302°F)  -40 to +55°C (-40 to 131°F)  +10 to +55°C (50 to 301°F)
Humidity  0-99% RH non-condensing  0-90% RH
Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
Response time T90
Operating voltage  2.0V dc +/- 0.1V (Typical)  10-30V dc
Power requirements 300mA (Typical)  50mA at 24V dc 1.2W
Electrical output 3- wire mV bridgeTypical signal: >10mV/%LEL CH4  3- wire 4-20mA (current sink or source)
Approvals ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
GOST-R
EMC compliance EN 50270FCC Part 15    ICES- 003

*3/4 ” cable entry only available on aluminium juntion boxes.