GD10P CO2 Infrared Gas Detector

Simtronics

General Details

HART_Protocol_logo300dpi

The GD10P-CO2 has been designed with features that provide an effective response to the detection of CO2 in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.
The GD10P-CO2 differs from all other point infrared gas detectors, because they utilise silicon based solid-state sources. 
The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
We offer the longest combined detector and IR source warranty on the market.
Supplied with worldwide hazardous area approvals. Suitable for use in SIL 2 systems.
An industry standard HART® interface is used for configuration of special fault levels as well as access to extended maintenance data.

 

Features
  • 15 years warranty IR sources – solid state optics
  • Selectable response rate, without  predictive software
  • Individually heated sapphire mirror (not conducted heat)
  • No field recalibration
  • Dual skin weather protector – no filters / gauzes or sinters
  • Planned maintenance with HART
Application
  • FPSO / FSO / MOPU
  • Oil & Gas Offshore
  • Marine / Jack Up Rigs
  • Oil & Gas Onshore
  • Chemical and Petrochemical Plants
  • Waste Disposal
  • Gas Turbines
  • General Industry
Specifications
GENERAL
Type Gas detector
Product GD10P
Product code GD10-P00-23BG-0X*-00
Manufacturer Simtronics
GAS DETECTOR
Type Point Infrared Gas Detector
Design principle IR-absorption, Dual wavelength and dual path
IR Source Solid state (SimSource), 50Hz sampling rate, long life – 15 years warranty
Detected gases Carbon Dioxide
Calibrated range 0 – 100% Volume Carbon Dioxide (CO2)
Weather protector Sample flow cell recommended.  Sinters, gauzes or hydrophobic filters shall not be used.
PERFORMANCE
Lifetime stability ±5% FS reading (std)
Accuracy ±5% FS between 0-50% reading, ±7% FS between 50-100% reading (std)
Response time (5s – std) T20 = 1.0 sec  /  T50 = 2.5 sec  /  T90: 6 sec
Response time (1s – fast) T20 = 0.3 sec  /  T50 = 0.7 sec  /  T90 = 1.6 sec  (Configured via HART®)
Calibration interval Fixed factory calibrated. No field calibration required.
ELECTRICAL
Power supply 24V DC, range (18 – 32V DC)
Power consumption 140 mA typical
Cable entry 2x M20, one entry with Exe plug
Junction box Integrated Exe junction box.
Connection 0.3 mm2 (22 AWG) – 1.5 mm2 (16 AWG), 3 wires
Analogue output signal 0-20mA, max. load impedance 500Ω.
Fault signalling Diagnosis signalling in the 0.4 – 3.0mA range. Dirty optics / Early-dirty optics – selectable
Maintenance interface HART v6.0 Universal Commands (HART version)
ENVIRONMENT
Storage -40°C to +70°C (-40°F to 158°F)
Operation -20°C to +65°C (-4°F to 149°F)
Humidity 100% RH (non-condensing)
Ingress IP66 / IP67  DIN 40050
RFI/EMI Complies with EN50081-1 and EN50082-2.
HOUSING
Ex Classification EEx de IIC T6
Material 316 L stainless steel
Weight 2.9 kg (6.4 lbs)
Dimensions 264L x 104W x 106H (mm)*10.4 x 4.1 x 4.2 (inches)
APPROVALS
ATEX Certificate Nemko 07ATEX1438
IECEx Certificate IECEx NEM 07.0006
CSA Certificate 1773527
SIL Suitable for use in SIL3 systems
Other ABS, INMETRO (UL variant available)
ACCESSORIES
499-811938 Duct mount flange kit
499-810874 Sample flow housing
499-813397 Mosquito net
499-815712 Sunshade