TITAN Benzene Specific Monitor

General Details

TITAN

The world’s first continuous, benzene specific monitor

Set to change the game in refinery application, Titan is the first truly selective benzene monitor on the market.

Titan is fixed, continuous, real-time benzene specific monitor designed for petrochemical environments, providing the ultimate device for plant and workforce.

The instrument is wall-mounted with a dynamic range detecting benzene for 0.1 – 20 ppm. Titan samples gas from the environment once per minute and within just 60 seconds an accurate benzene measurement is displayed.

Titan provides an immediate warning alarm system with two operator configurable levels, ensuring workers are kept safe and protected to the standards required on site. The instrument incorporates two relay outputs allowing the operator to install their own required alarm system.

Titan’s continuous, real-time measurement allows trends over time to be monitored and communicated via 4-20 mA or RS485. Data is stored internally and can be downloaded remotely for analysis.

Designed to be easily installed and serviced, the modular design allows the Ex d case to be installed well in advance of commissioning. The service module can be removed and replaced as a remotely serviceable plug and play cartridge.

Titan incorporates Ion Science market leading MiniPID sensor technology with proven resistance to humidity and contamination, ensuring optimal performance whatever the environment.

Features

The only truly selective wall-mounted benzene monitor

  • Fast and accurate detection of benzene down to 0.1 ppm
  • Minute by minute sampling providing continuous real-time data
  • Robust separation method ensures benzene specific readings
  • Internally regulated heating for stable operation at extreme temperatures

Safety

  • Clear display & visual alarms for indication of benzene levels
  • Two user-definable independent alarm levels including optional real-time STEL calculation
  • Two relay outputs provide an immediate warning alarm
  • Meets ATEX & IECEx approvals (CSA approval pending

Ease of use & service

  • Modular design for ease of installation and servicing
  • Service-free six months operation
  • Simple two button interface for menu navigation
  • No consumables

Best available photoionisation (PID) detection

  • PID independently verified as best performing on the market
  • In-built humidity resistance with no need to compensate
  • Anti-contamination design for extended field operation
Specifications

SENSOR TYPE
PID, 10.6 eV lamp coupled with selective filtering

SELECTIVITY
Benzene specific within typical petrochemical matrix RANGE 0 – 20 ppm

MEASURING FREQUENCY
One minute

LOWER LIMIT OF DETECTION
0.1 ppm ACCURACY ± 0.05 ppm or ± 10%, whichever is greater

TEMPERATURE STABILITY
Internally heated

SAMPLE FLOW
200 ml/min

DISPLAY
Graphical BW LCD 64 x 128 pixels with back light
Bright LEDs for normal operation, fault and alarm
Two ­­­magnetic switches for menu operation

HAZARDOUS AREA SAFETY APPROVALS
ATEX/IECEx: II 2G Ex d II B+H2 T4 Gb (-20 oC to +55 oC)

INGRESS PROTECTION RATING
Designed to IP65 (cable gland dependant)

HUMIDITY
0 – 100 % RH

MINIMUM SERVICE PERIOD
Selective filter six months
PID lamp one year

CABLE ENTRY
Two 3/4 NPT gland threads

POWER   
Vin (nom) 24 V DC @ 3.2 A (recommended)
Vin (max) 32 V DC @ 2.4 A
Vin (min) 19 V DC @ 4.0 A

COMMUNICATION
Isolated 4-20 mA output
Isolated RS 485 Modbus (simplex/half duplex or fully duplex)
USB when lid removed with PC software DATA

STORAGE
On board MMC, minimum of six months

RELAY OUTPUT
Two isolated outputs, voltage free, 24 V DC @ 1.25 A max

WEIGHT AND DIMENSIONS
15 kg (33 lbs)
219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.)

GAS SAMPLE LINE
10 m max length, PTFE, 6 mm OD, 4 mm ID Luer fitting

Applications

The Titan Specific Benzene Monitor can be used to detect gases across a wide range of industries and applications, including:

  • Oil & gas
  • Petrochemical
  • Chemical
  • Health & safety
  • Offshore