The Slick Sleuth™ SS300 is used in a wide variety of industrial and environmental applications for remote detection of oil leaks and spills. The Slick Sleuth SS300 provides real-time detection and alarm notification, enabling users to contain the leak or spill, thereby averting environmental damages, costly cleanup, fines, regulatory penalties and negative publicity.
The Slick Sleuth SS300’s optical sensor detects small (micron-level) amount of oil in real-time and can send signals to automatically activate or deactivate pumps, open or close valves, activate audio/visual alarms and send alarms to remote locations over wireless communications (radio telemetry or cellular networks). The Slick Sleuth SS300 can also be interfaced to the facility’s central monitoring and control system (SCADA, PLC, etc.).
click to enlarge
Model: | SS300 – Slick Sleuth |
Operation: | Automated, Optical, Non-Contact Sensor Patented UV Filter-Fluorometer Methodology Oil On Water Detection: Crude, Lube, Hydraulic, Jet/Aviation, Diesel, Fuel Oil, Turbine, Transformer, and Many Others (contact factory to inquire about types of oil detected) |
Sensitivity: | 3 +/- Micron Sheen User Adjustable Sensitivity Discrete Alarm and/or Scaled Signal Output |
Detection Range: | 1-to-5 Meters (Distance Above Surface) |
Operating Temp: | -10 to +60 °C (Standard) -20 to +60 °C (Optional) |
Enclosure: | Stainless Steel
NEMA 4X, IP66, Weatherproof Housing External Ports: Power In, Signal Out, USB Serial Interface 4-Corner Mounting Tabs |
Purge Compatible: | Purge System for Hazardous Gas Locations (Contact Factory) |
Dimensions: | Approx. 8¼” x 12¼” x 15½” / 21cm x 31cm x 39cm (D x W x H) |
Weight: | Approx. 30 lbs / 13 kg |
Input Power: | 85–264 VAC, 50/60 Hz (DC Option Available – Contact Factory) |
UV Light Source: | Xenon Flash Used to Generate a Collimated Beam |
UV Flash Life: | 2.5 Years (typical) at Highest Sampling Rate (e.g. 2 Hz) |
Outputs: | Local Status and Alarm Indicators(Red/Green LEDs)
Oil Detection Relay (DPDT), Equipment Status Relay (SPDT) Serial: USB, RS232, RS485 Current Loop / 0-20 mA (Optional) |
Wireless Options: | Radio, GSM/CDMA Cellular, Wi-Fi, Satellite – Contact Factory |
User Interface: | Sensor Operates Autonomously
Utility Program Used During Set-up and to Adjust Settings |
Base Station: | Slick Sleuth Base Station Software (Optional) |
Certifications: | Marked |
Initialization: | Magnetic Switching to Automatically Set Operation Point (no need to open housing during start up)Conforms to US EPA Standards (EPA/530/UST-90/009) Technology Patented by InterOcean Systems, Inc. |
Warranty: | 1-Year InterOcean Factory Warranty Standard |