The 4060 Series of Gas Chromatograph (GC) analyzers combine Teledyne’s field proven detector technologies with gas chromatography column separation capability. This enables reliable and repeatable of a single or multiple compounds in a stream containing interfering components.
Flame-ionization detector (FID) or thermal conductivity detector (TCD) options enable part-per-billion (ppb), part-per-million (ppm) or percent levels of detection depending on application. The analyzer includes an integral temperature-controlled sample system of 316SS and Teflon construction to provide a suitable sample to the detector. Contact TAI for other available materials.
- Field-proven microprocessor-based electronics with menu-driven functionality
- Easy-to-view 5-digit LED display for readings
- 2 x 20 vacuum fluorescent display for menu options, settings and status
- 0-1 VDC and 4-20mA (isolated) analog outputs and gas identification outputs
- RS-232 duplex digital output
- Two fully-configurable concentration alarms and one system alarm, all with Form-C relay contacts
- Built-in diagnostic capability
- Auto-calibration and remote-calibration ready (integral valves available)
4060/FID | 4060/TC |
Acetaldehyde | Argon (purity and impurity levels) |
Benzene | Carbon Dioxide |
Butane | Carbon Monoxide |
Carbon Dioxide – (measurement achieved with methanizer) | Helium |
Carbon Monoxide – (measurement achieved with methanizer) | Hydrogen |
Ethane | Hydrogen Sulfide |
Ethyl Benzene | Krypton |
Ethylene | Nitrogen (purity and impurity levels) |
Hexane | Xenon |
Methane | |
Methanol | |
MTBE | |
Propane | |
Propylene | |
Toluene | |
VOCs | |
Xylene |
- Ambient benzene, BTEX detection
- Beverage-grade carbon dioxide: detection of ppb benzene, acetaldehyde, methanol and VCM in beverage-grade carbon dioxide to ISBT specification
- Methane / non-methane hydrocarbon monitoring
- Nitrogen or Argon purity
- C1-C4 levels in natural gas or syngas production
- LNG impurity detection
- MTBE monitoring in gasoline
- Hydrogen detection in a mixed fuel gas
Chromatography Software – Tracs™
Tracs™ software developed by TAI provides all features and functionality needed to view and analyze chromatography data. When installed on a PC computer, Tracs™ collects digitized data fed from the analyzer with which it can plot chromatograms, perform analytical calculations, log data, and save information for future use.
Features include:
- Bi-directional communication of analyzer’s range, alarm and timing settings which can be remotely uploaded and downloaded
- Acquires real-time raw data for continuous display of chromatograms
- Chromatograms can be superimposed upon one another to verify repeatability
- Elution peaks can be displayed within their own respective timing frames or individually manipulated for optimal peak scrutinization
- Statistical summary including analytical calculation of measurements, distribution of values and deviations
- Data-logging
- Saving and retrieving of digitized data files
4060/FID | 4060/TC | |
Sensing Technology | Flame-Ionization Detector (FID) | Thermal Conductivity Detector (TCD) |
Gas and Ranges | Hydrocarbon compounds Trace or percent level detection (Contact factory to verify application) |
Most gases Trace or percent level detection (Contact factory to verify application) |
Sensitivity | 1% of full-scale | 1% of full-scale |
Accuracy | ± 2% of full-scale (at constant temperature) |
± 2% of full-scale (at constant temperature) |
Repeatability | 1% of full-scale through all ranges | 1% of full-scale through all ranges |
Response Time | Application Dependent | Application Dependent |
Operating Temperature | 40-110°F (4-43°C) | 40-110°F (4-43°C) |
Zero and Span Noise | Less than 0.5% of full-scale | Less than 0.5% of full-scale |
Zero and Span Drift | 2% of full-scale per week | 2% of full-scale per week |
Analog Outputs | 0-1 VDC and 4-20 mADC isolated (one output with Gas ID for 3+ gases) |
0-1 VDC and 4-20 mADC isolated (one output with Gas ID for 3+ gases) |
Alarms | One system alarm and two concentration alarms. Form-C relays rated @ 3A 250VAC resistive |
One system alarm and two concentration alarms. Form-C relays rated @ 3A 250VAC resistive |
Supply Voltage | 110 or 220 VAC 50/60 Hz | 110 or 220 VAC 50/60 Hz |
Maximum Power Consumption | 600 VA | 600 VA |
Maximum Load Impedance of 4-20 mA Output |
500 ohms | 500 ohms |
Sample Flow Rate | 1 SCFH (0.5 LPM) standard | 1 SCFH (0.5 LPM) standard |
Dimensions | 19” W x 8.75” H x 22.5” D (483 x 222 x 572mm) |
19” W x 8.75” H x 16.5” D (483 x 222 x 419mm) |